Digital TDS3 TDS-3 TDS Meter water
Digital TDS3 TDS-3 TDS Meter waterTDS3 TDS-3 TDS Meter water tester Pen LCD Digital Temp PPM Meter Tester
Ideal for commercial use. Has a carrying case with a belt clip.
Highly efficient and correct due to its advanced microprocessor technology.
The hold function saves measurements for convenient reading and recording.
The meter shuts off automatically after 10 minutes of non-use to conserve batteries. The measurement range is 0-9990 ppm. From 0-999 ppm, the resolution is in increments of 1 ppm. From 1000 to 9990 ppm, the resolution is in increments of 10ppm, indicated by a blinking ‘ x10’ image. Built-in digital thermometer Large and easy-to-read LCD screen. Calibrated with a 342 ppm NaCl solution. Meters can be re-calibrated with a mini-screwdriver.
pH-mV-Cond-TDS-Salt and Temp Meter
pH-mV-Cond-TDS-Salt and Temp MeterThe special waterproof connector which has four different electrodes(pH, ORP, Conductivity, TDS, and Temperature ) can be plugged into and automatically recognized.
TDS D2 Water Quality Monitor
TDS D2 Water Quality MonitorTDS D2 Water Quality Monitor
TDS D2 Water Quality MonitorSwitch 0: Screen no display Switch 1 and 2: for the first time, turn the switch to 1 and get the reading, and then also check Switch 2 reading The reading difference between 1 and 2 can specify to be raw water or filtered water.
Inline Digital TDS Meter
Inline Digital TDS MeterNow Check instantly your water purifier water Quality at your own with most reliable inline HM Digital TDS meter
200 GPD RO Membrane
200 GPD RO MembraneReverse Osmosis Ultra Flow Commercial RO Membrane Vontron ULP-2812- 200 GPD
75 GPD REVERSE OSMOSIS MEMBRANE – DOW FILMTEC
75 GPD REVERSE OSMOSIS MEMBRANE – DOW FILMTEC75 GPD REVERSE OSMOSIS MEMBRANE – DOW FILMTEC
75 GPD REVERSE OSMOSIS MEMBRANE – DOW FILMTECThe Dow FILMTEC Residential Membrane elements are designed to provide your home with safe, clean cooking and drinking water. This Polyamide (TFC) Thin Film Composite, standard 2″ diameter elements have been tested and Certified by NSF International against NSF/ANSI Standard 58 for material requirements only.
Alkaline Filter Cartridge PH 8.5 – 9.5
Alkaline Filter Cartridge PH 8.5 – 9.5good quality ph 8.5-9.5 alkaline filter cartridge/alkaline mineral water filter cartridge
Increase the pH of the filtered water typically to between 8.5 and 9.5. Changing the oxidation/ reduction potential of the water (ORP) to between -100mV and -250mV. There give the water antioxidant properties. The antioxidant effect is due to the release of molecular hydrogen, which research shows is very powerful. Decreasing the size of the clusters of water molecules so that the water is absorbed more in the body. Setting into the water beneficial alkaline minerals such as potassium, magnesium, and calcium.
Reverse Osmosis Water Dispenser For Office
Reverse Osmosis Water Dispenser For OfficeReverse Osmosis Water Dispenser For Office
Reverse Osmosis Water Dispenser For OfficeHot Cold and Normal RO Water Purifier – White Made in Taiwan
Two-thirds of water purifies water by RO and mineral technology. Tds keeps the necessary mineral for water. The mineral is essential for the body, so this RO Dispenser is unique and non-competitive in the RO world. The water purifier removes all dissolved chemicals, Heavy metals,s and arsenic in the water.No hand and is hand-operated automatically without touching. RO, which purifies water, is like a transparent crystal granule. Distributing all kinds of damaged particles creates 99.99% pure water.
Lab Zero PPM Automatic Water Distiller
Lab Zero PPM Automatic Water DistillerLab Zero PPM Automatic Water Distiller
Lab Zero PPM Automatic Water DistillerA Highly Recommended System for Laboratory/aquarium and small-capacity chemical processing units.
Aquarium RO DI 6 Stages 0PPM 100 GPD System
Aquarium RO DI 6 Stages 0PPM 100 GPD SystemAquarium RO DI 6 Stages 0PPM 100 GPD System
Aquarium RO DI 6 Stages 0PPM 100 GPD SystemDI is Demineralization by Ionization. A DI filter removes the few mineral ions that make it through the RO membrane; this makes sure that the water is as pure as possible. The DI filter also removes nitrates that are not removed by the membrane. The DI filter is a cartridge filled with an ion exchange resin in the form of small beads. When the water passes by the beads, the minerals and other ions leave the water and attach to the beads.
Automatic flushing controller
Automatic flushing controllerThe purpose of the flush system is to help prevent scaling or fouling of the RO membrane(s) by providing a rapid rinse which washes away impurities and keeps the membrane clean.The auto flush system noticeably increases the service life of the membranes in reverse osmosis systems.
Industrial Automatic Control Panel
Industrial Automatic Control PanelIndustrial Automatic Control Panel
Industrial Automatic Control PanelThe Control panel is the main controller of the RO System, it controls the working and synchronizes all the equipment in a Particular sequence to perform the Water purification.
1500 GPD upto 2000 GPD RO System
1500 GPD upto 2000 GPD RO SystemRO systems are powerful systems that are capable of taking out large amounts of salt, minerals, and other contaminants from water sources such as wells, rivers, and lakes. To master this mission, the systems take use of a popular technology known as “reverse osmosis”. Reverse osmosis is ordered with the reversal of a natural process known as “osmosis”. Osmosis is ordered by nature to transport salt through a semi-permeable membrane from an area of low solute concentration to an area of higher solute concentration in order to gain an even amount of solute concentration on both sides of the membrane. Reverse osmosis combats osmosis via a pressure pump that exerts high pressure on the highly concentrated side of the semi-permeable membrane, moving only water molecules through the small pores of the membrane while salts, organics, and other contaminants are denied passage.
3000 upto 4000 GPD RO System
3000 upto 4000 GPD RO SystemA commercial Reverse Osmosis system was supplied to a major company in GCC and African Countries. From its initial start-up, the machine has been working properly with minimal troubleshooting. A quality reverse osmosis machine is designed to deliver high-quality service by removing massive amounts of salt and other impurities from wells, lakes, rivers, and the ocean through a process called ‘reverse osmosis”.
4500G upto 5500 GPD
4500G upto 5500 GPDIf you already realize that there is a lot more to a reverse osmosis system than just reverse osmosis, then you will understand why this is the best reverse osmosis system for applications from 500 Gallons per days to 5,000 Gallons per day. The most important component of a reverse osmosis system is the pre-treatment. The chlorine and organics need to be removed and a water softener or anti-scalant system (we greatly prefer anti-scalant) has to be installed ahead of the reverse osmosis system itself.
14000 GPD upto 16000 GPD RO System
14000 GPD upto 16000 GPD RO System14000 GPD upto 16000 GPD RO System
14000 GPD upto 16000 GPD RO SystemExtra low-energy reverse osmosis system (14,000 GPD) are designed to deliver high quality water at low operating costs for municipal and industrial water applications. Its high active area design coupled with the highly productive membrane allows it to operate at half the feed pressure of standard RO elements and up to 30% lower pressure compared to other low energy RO System.
10000 & 12000 GPD RO System
10000 & 12000 GPD RO System10000 & 12000 GPD RO System
10000 & 12000 GPD RO SystemDesigned to produce low dissolved solids water from tap or well water, these Small Commercial RO systems use high efficiency reverse osmosis membranes. L-series RO systems are designed to work at pressures of 200-250 psi for higher TDS water and use TW reverse osmosis membranes. The TW RO membranes offer higher salt removal and the higher operating pressure overcomes the loss of membrane flow due to higher TDS level.
Myron Ultra Meter II 6P
Myron Ultra Meter II 6P3 solution standards for greatest accuracy in diverse applications
Fully automatic temperature compensation
User adjustable temperature compensation (up to 9.99%°C)
which also allows TC to be disabled for applications requiring non-compensated readings.